Both AUS 40 and AUS 32 are solutions of high-purity urea in deionized water, and both feed Selective Catalytic Reduction (SCR) systems that cut NOx emissions. But they are not interchangeable. Here is a clear comparison for fleet owners, ship operators and anyone planning a DEF business.
| Feature | AUS 40 – Marine DEF | AUS 32 – DEF / AdBlue |
|---|---|---|
| Urea content | About 40% | 32.5% |
| Water | About 60% deionized water | 67.5% deionized water |
| Quality standard | ISO 18611-1 | ISO 22241-1 (BIS in India) |
| Crystallisation | Approx. 0 °C | Approx. −11 °C |
| Main users | Ships, ferries, tugs, offshore vessels, rail, gensets | BS-VI trucks, buses, cars, tractors, construction equipment |
| Driving regulation | IMO MARPOL Annex VI – NOx Tier III | Bharat Stage VI / Euro VI / CEV & TREM norms |
| Typical pack sizes | 210 L drums, 1000 L IBC, bulk | 10–20 L cans, 210 L drums, IBC, bulk |
AUS 40 carries roughly 23% more urea per litre than AUS 32. On a ship that burns huge quantities of fuel, that means meaningfully smaller urea tanks for the same NOx reduction — valuable when every cubic metre on board earns money.
AUS 32 is the eutectic mixture, so it has the lowest possible freezing point of any urea-water mix (about −11 °C). That is why road vehicles, which park outdoors in winter, use it. AUS 40 begins to crystallise at about 0 °C, which is acceptable inside heated engine rooms but not in a truck tank on a winter highway.
AUS 32 is governed by ISO 22241 and, in India, BIS certification — ActiveBlue is a BIS certified DEF manufacturer. AUS 40 is governed by ISO 18611. Impurity limits are similar in spirit: both standards guard the SCR catalyst against metals, phosphate, biuret and insolubles.
Only if the SCR maker approves it. The dosing system is calibrated for a specific concentration; using AUS 32 in an AUS 40 system means under-dosing urea, which can push NOx above the permitted limit.
No. Vehicle SCR systems are calibrated for AUS 32 (ISO 22241). AUS 40 would over-dose, can crystallise in cold weather and may trigger fault codes or damage the system.
In a controlled plant with deionized water and laboratory testing, a manufacturer can adjust concentration. It should never be done on board or with tap water, because impurities would put the product out of specification.